Roof Systems

Commercial roof systems for Franklin, TN: TPO, PVC, EPDM, modified bitumen, built-up, metal, spray foam and coatings, matched to how each one fails.

Roof Systems in Franklin
  • TPO Roofing
  • PVC Roofing
  • EPDM Roofing
  • KEE Roofing
  • Modified Bitumen Roofing
  • Built-Up Roofing (BUR)
  • Standing Seam Metal Roofing
  • Metal Roof Retrofit and Restoration
  • Spray Polyurethane Foam Roofing
  • Silicone Roof Coatings
  • Acrylic Roof Coatings

A chalky white film on a single-ply roof, or a seam that has gone stiff and glassy, tells you a membrane has aged. Which membrane it is changes everything that follows, because each system fails in its own sequence. In Franklin, TN, with about 54 inches of rain a year and July highs near 91 degrees, the membrane is working every day, and the way it wears out is what separates one system from the next.

Single-ply membranes

Single-ply sheets are the common choice for low-slope commercial roofs, including the large office and retail buildings around Cool Springs. TPO and PVC are heat-welded at the seams, which makes them strong when the weld is clean and weak where dirt or damp got in. EPDM is a rubber sheet that relies on adhesives and tape at the laps, and KEE is a PVC-family sheet with a blended polymer that resists the oils and fats that kitchen exhausts leave behind.

Layered and built-up roofs

On layered roofs, modified bitumen and built-up roofing among them, the failure comes slowly: surface granules wear, felts blister and flashings pull away from walls. Reading that pattern on the roof, before anything is opened, is how a patch is chosen over a tear-off.

Metal and foam

Standing seam metal sheds water well, but its clips, panel ends and penetrations are where it leaks. A metal retrofit can go over an older flat roof when the structure allows it. Spray foam builds an insulating layer without laps that needs a protective topcoat.

Liquid coatings

Silicone handles standing water better than most coatings. Acrylic reflects heat well on a dry roof. Neither one rescues a roof with wet insulation underneath, which is why the moisture survey comes first.

Wind and storm exposure

Brentwood's place in the Dixie Alley tornado zone is a reminder that wind is a design load in this part of Middle Tennessee. The August 2023 EF0 near Highway 96 and Royal Oaks Boulevard left minor roof damage on some businesses. Edge metal, seam strength and fastener patterns decide how a system holds in that wind, so a wind damage repair starts at the perimeter.

Commercial Roofing Questions

Which membrane lasts longest in Franklin heat?

No membrane wins on its own. Welded seams that were made clean, drains that stay open and a surface that is not left ponded matter more than the sheet name on the invoice.

Can I put a new membrane over the old one?

Sometimes. The test is dry insulation. A recover goes over a sound, dry base, and a wet one has to be cut out first.

Why does the foam or coating need a moisture survey first?

Because liquid and foam systems trap whatever is under them. Wet insulation sealed beneath a coating stays wet and starts the next leak.

What fails first on a metal roof?

Usually a fastener, clip or flashing at a penetration rather than the panel itself. We trace the leak back along the panel seam to the opening, whether the building sits on Carothers Parkway or out in Southall.

Call us today555-555-5555